RIA: One Community’s Experience




The Reamer Irrigator Aspirator (RIA) has three main indications in our community trauma practice. The most common indication for RIA is harvesting of autololgous bone graft from the femur for nonstructural bone graft. The second most common indication is for irrigation and debridement of intramedullary osteomyelitis. The final indication for RIA is for acute nailing of femoral shaft fractures in patients with multiple long bone fractures with or without pulmonary injury. If one pays careful attention to the details of the technique, RIA is a safe and effective method of harvesting autologous bone graft with minimal morbidity. Autologous bone graft harvested with RIA is our graft of choice for nearly all of our bone grafting cases.


The patients discussed in this article were all treated at a level 2 community trauma center located in a suburb of a moderately sized city and serves a community of 1 million persons. With only a few exceptions, the authors are the only users of the Reamer Irrigator Aspirator (RIA) at our hospital. All the authors are fellowship-trained orthopedic trauma surgeons and have practices that are approximately 85% acute trauma and 15% reconstructive and elective general orthopedics. The authors work directly with the general trauma surgeons on the trauma service and have a separate call schedule from the general orthopedic surgeons. The trauma service has an average of 1200 trauma admissions per year. The authors began using RIA in 2003 and, as in many of the centers using RIA shortly after its release, the authors primarily used RIA for the acute treatment of femur and tibia fractures in polytrauma patients with chest injury or with two or more long bone fractures. The general trauma surgeons were highly influential in convincing the hospital of the importance of RIA for our severely injured patients with long bone fractures.


As experience and early reports were disseminated about the benefits of RIA as a bone-harvesting instrument, we began to use RIA increasingly more as a bone graft harvesting tool. The authors have been reluctant to abandon autologous bone graft in favor of the ever-increasing array of bone graft substitutes because of our belief that autologous bone with all of its bone-promoting components is ideal for bone healing. This core belief in addition to the low donor site morbidity of RIA seen in our patients has made RIA-harvested bone graft our graft of choice for most reconstructive surgeries not requiring structural properties.


Indications


Our group has three main indications for RIA: harvesting of nonstructural bone graft, treating acute or chronic intramedullary infection, and intramedullary nailing of multiple long bone fractures or in patients with a chest contusion and one or more long bone fractures.


In our practice, the most common indication for RIA is for bone graft harvesting. We believe that autologous bone graft is the best bone graft for most bone-healing applications. Because the graft material obtained with RIA is a granular material with varying degrees of gelatinous consistency, it is not useful as a structural graft. Tri-cortical iliac crest or allograft blocks are better suited for this purpose. However, if bone graft material is needed for healing of bone defects, nonunions, and so forth, autologous bone graft harvested with RIA is our first choice. We believe that cortical-cancellous bone harvested from the medullary canal of femurs provides a bone graft with osteogenic, osteoconductive, and osteoinductive properties. Given the minimal morbidity with harvesting this rich bone graft using RIA, we prefer it to demineralized bone matrix, bone morphogenic proteins, solid allograft preparations, or combinations of these materials. We cannot rationalize using bone graft substitutes in an attempt to mimic autologous bone graft when we can harvest the real thing with little risk and morbidity to the patient. In addition, the volume of graft obtained with RIA can be abundant but can also be voluntarily adjusted to need based on reamer size. On the other hand, the volume of graft harvested with RIA may be limited because of patient age (osteopenia) and systemic diseases that affect bone quality.


Although not one of the early applications of RIA, we have used RIA as a tool to debride and irrigate the medullary canals of long bone infections. We have used RIA in both the femur and tibia and believe that it can debride the entire medullary canal and irrigate and remove the infectious material in an efficient single technique. The suction/aspiration feature of RIA minimizes pressurization of the canal, which theoretically decreases or eliminates dissemination of the infected material deeper into the cortical bone or into the circulation.


As alluded to earlier, we still use RIA in selected acute long bone fractures. Because of anecdotal reports of increased nonunion rates in acute fractures, we do not use RIA for isolated femur fractures. Although this nonunion concern is unproven and unsubstantiated, we do not feel there is any advantage to RIA for acute femoral nailing in isolated femur fractures; however, if a patient with a femur fracture has a significant pulmonary contusion, we would choose to use RIA in an effort to decrease or eliminate marrow embolism. The other acute fracture indication is in patients with bilateral femur fractures with or without associated tibia fractures. However, we have not used RIA in patients with lung injury or multiple long bone fractures in the past 2 years mainly because of our practice of damage control orthopedic procedures (provisional external fixation with delayed intramedullary nailing) in these at-risk and borderline patients. Because the negative effects of marrow embolism associated with reaming of tibia fractures are not as clearly defined as they are in reaming of the femur fractures, we do not feel that RIA is indicated for acute tibia fractures associated with pulmonary injury. The technique of RIA in tibias is much more difficult because the smallest reamer size is 12 mm and because of the eccentric starting point and relatively acute turn that the reamer needs to make in the proximal tibia. The rigid 5 to 6 cm at the tip of the RIA and semi-rigid tube reduces the flexibility of the RIA and increases the chance of a complication when used in the tibia. However, with a retro-patellar entry point technique, these complications may possibly be eliminated. We have not used retro-patellar technique to date, but we would consider it if we decided we needed to use RIA in the tibia.




Technique of harvesting intramedullary bone with the Reamer Irrigator Aspirator


RIA-harvested bone graft is obtained through a system that incorporates a nitinol drive shaft, a single-use sharp reaming head, and a disposable plastic tube. The components are assembled in a manner that allows the delivery of a cooling irrigant, usually 0.9% normal saline, through the center portion of the nitinol shaft and out through the center port of the reamer head through gravity feed. While spinning in a high-speed, low-torque manner, the reamings become mixed with the irrigant solution and are aspirated through several ports in the sides of the reamer head, out through the plastic tube that surrounds the drive shaft, and into an inline collection filter.


When choosing a starting point for obtaining RIA graft, we consider several options. We often choose an ipsilateral site when harvesting for a lower extremity graft to minimize immobility. When femoral RIA harvesting is used for upper extremity grafts, the desire of the patient is taken into consideration (ie, right versus left), when possible. In aseptic nonunions of the femur, after hardware has been removed, that same ipsilateral femur may be harvested to obtain graft, with the understanding that the yield may be lower. The tibia is not usually used for obtaining graft for concern of thinning the posterior cortex as the bone is harvested, although it has been used on multiple occasions for debridement of endosteal infection within the tibia, where the leg is supported by splinting or other means after debridement.


Hence, we obtain most RIA graft harvestings from the femur, through one of four different starting points. Proximal starting points consist of the piriformis fossa and the greater trochanter, with a larger number of trochanteric start points for ease of manipulating the stiff plastic/nitinol assembly, ease of obtaining the starting point correctly, and with the perception that the trochanteric cortical bone is thinner and cancellous bone more abundant than the piriformis region, yielding more graft from the proximal femur. These two sites mirror those starting points used for antegrade femoral nailing. The distal femoral sites are either an extra-articular medial starting point, chosen to avoid violating the knee joint anterior and proximal to the insertion of the medial collateral ligament, or an intra-articular site anterior to the anterior cruciate ligament (ACL), in a manner identical to our retrograde femoral nailing entry point.


We position the patient supine on a radiolucent table, and use the fluoroscope to confirm the proper starting point and assist with determining reamer head size. With proximal femoral stating points, we place a small bump under the ipsilateral hip before sterile skin prep, and adduct the leg to ease insertion. To determine reamer head size, we place a radiolucent measurement guide (Synthes, Paoli, PA) against the side of the diaphysis, near its isthmus, at the same level as the bone. If placed on top of the thigh or leg, the body habitus of the patient may make the distance from the bone to the skin large enough to introduce error owing to differences in magnification. Depending on how much bone is anticipated to be required, we choose a reamer 1 to 2 mm larger than the endosteal canal width. The thickness of the cortex must be taken into account, so as not to introduce risk of fracture by overthinning of the cortex, especially with older patients.


We then introduce a 3.2-mm guide pin into the site and advance it enough to allow passage of a cannulated, fluted 6.0- to 10.0-mm step drill (Synthes). Once the canal is entered, we introduce a 2.5-mm ball-tipped reaming rod and confirm a center placement at the distal end by fluoroscopy, or in cases of multiple passes, we direct it toward the desired area of metaphyseal bone in one or the other femoral condyle. We pass the reamer slowly down the intramedullary canal in an “advance-withdraw” technique, where the reamer is advanced several centimeters, then withdrawn slightly, then advanced again, until reaching the opposite end of the canal. We take care to monitor the outflow of irrigant through the tube to ensure suction is not lost by clogging within the tube, which could cause malfunction of the RIA system or potentially harm the graft. This occurs commonly in younger patients with dense bone. We collect the reamings, but the effluent irrigant solution is not currently retained. Reamings are kept in a sealed container until use.

Only gold members can continue reading. Log In or Register to continue

Stay updated, free articles. Join our Telegram channel

Feb 23, 2017 | Posted by in ORTHOPEDIC | Comments Off on RIA: One Community’s Experience

Full access? Get Clinical Tree