Surgical Treatment Options: Mid-Shaft Fracture




Percutaneous Pinning



Connor G. Ziegler, MD
Robert A. Arciero, MD

Abstract


Midshaft clavicle fractures which require reduction and internal fixation can be managed using two primary approaches. Open reduction and internal fixation with one or more plates is one approach and intramedullary (IM) fixation is another option. IM fixation may be performed percutaneously or through a limited open approach. This chapter reviews the indications, techniques and potential complications of IM and percutaneous fixation of midshaft clavicle fractures.


Keywords: Clavicle Fracture, Intramedullary Fixation, Midshaft Clavicle, Percutaneous Pinning


This chapter is adapted from Basamania CJ, Rockwood CA Jr. Fractures of the clavicle. In: Rockwood CA Jr, Matsen FA, Wirth MA, Lippitt SB, Fehringer EV, Sperling JW, eds. Rockwood and Matsen’s The Shoulder . 5th ed. Philadelphia: Elsevier; 2017.


Introduction


Intramedullary (IM) pinning of clavicle fractures is a long-practiced technique with reported advantages over plate fixation, including reduced periosteal stripping, smaller skin incision, less risk to supraclavicular nerves, less bleeding, shorter surgical times, and healing via endochondral ossification (callus), which can be more easily assessed radiographically than direct bone healing (intramembranous ossification). A recent meta-analysis reported that IM fixation of midshaft clavicle fractures could achieve similar union rates and shoulder scores with superior surgical outcomes including significantly less time to union than plate fixation ( ). These findings remained constant when conducting subanalyses in only randomized controlled trials (RCTs). Significantly less blood loss, shorter operative time, smaller surgical wounds, and fewer complications in the IM group were also reported ( ).


Many surgeons may be reluctant to use IM clavicle fixation given past reports of major complications and perceived risk of pin migration. Randomized studies and a recent meta-analysis have reported both similar complication rates, as well as significantly lower overall and major complications with IM pinning versus plate fixation ( ). Nevertheless, there are numerous reports of IM device migration in clavicle fixation ( ). Skin and soft tissue irritation resulting from migration, telescoping, or hardware protrusion represents one of the chief complications with IM fixation ( ). The dilemma of IM fixation, unlike plate fixation, is that nail removal is often intended after the fracture has healed. The challenge with this is that the device needs to have a low profile so it does not cause irritation, but it must be prominent enough to be easily retrieved. Unlike plate and screw constructs, IM fixation can be removed under light sedation and local anesthesia. With current techniques and implants, IM devices are reported to have a low rate of unplanned revision surgery and to be a safe and effective form of fixation ( ).


Construct rigidity is a concern particularly when treating contact athletes who are at risk for refracture. In the setting of comminution, the cantilever effect for a pin extends to the medial-most portion of the pin, thereby providing fixation in bending loads. It also allows axial compression, which should enhance healing. However, reported superior biomechanics to bending and torsional forces with plate versus IM fixation in a cadaveric midshaft clavicle fracture model ( ). In contrast, reported that failure torques of IM repair and plate repair were not significantly different; however, failure torque after IM device removal was significantly greater than after plate removal ( ). Nevertheless, IM pinning is a viable fixation option in athletes, particularly considering recent data that suggest shorter time to union and lower rate of complications.


Management


The management of midshaft clavicle fractures should be individualized to the patient’s goals and activity level. The primary surgical indications for open reduction internal fixation of midshaft clavicle fractures include shortening greater than 2 cm, 100% or greater fracture displacement, and fracture comminution ( ). In athletes, prolonged recovery and deficit in shoulder strength are often poorly tolerated, making surgery the typically preferred treatment. For most midshaft fractures that do not have excessive comminution or obliquity to the fracture planes, IM fixation is an excellent option to minimize fragment stripping, avoid supraclavicular nerves, achieve relative stability, and improve cosmesis. Complex, comminuted fractures, however, are not appropriate for IM nailing, with reported difficulties achieving and securing accurate reduction ( ). In such cases, surgeons should consider plate fixation. The primary IM options include smooth, threaded, and partially threaded devices. These can be rigid or flexible and, in the case of hybrid fixation, can have flexible and rigid components. Despite having less risk of migration than smooth devices, fully threaded devices are seldom used because of the risk of gapping at the fracture site, which can impede healing ( ). There are numerous reports of migration of smooth devices used in clavicle fixation ( ). If these devices are used, they need to be followed closely for any radiographic signs of migration. Although smooth pin fixation has declined in popularity, the use of smooth titanium elastic nails (TENs) gained popularity in the 2000s in treating clavicle fractures ( ). One of the primary advantages in using a flexible nail is that it allows considerable length of fixation as compared with a rigid device. Despite this, there remains the risk of implant migration, and some studies show a rate of loosening or migration of 4% to 25% ( ). The addition of a hybrid fixation has alleviated many of the problems associated with IM pinning with improved length and rotational control over other IM devices and the ability to place an interlocking screw for increased rigidity and rotational control ( ).


Two important determinants of IM fixation are the diameter of the IM canal and the length of fixation. The IM canal determines the maximum size of the device. For the pin to travel the most effective length, it makes three-point contact with the walls of the canal: anterolaterally, then posteriorly at the apex of the posterior curve, and then again anteromedially when it contacts the anteromedial curve. An important relationship exists with a larger diameter IM fixation, whether it is a screw, pin, or smooth wire; namely, it will be stiffer but potentially allow less fixation length. There will also be greater stresses with short fixation, which could lead to increased risk of loosening, failure of the fixation, and healing. Significantly increased length of fixation with significantly more fixation in the lateral fragment has been reported using a 3.2-mm pin compared with a 4.0-mm pin ( ). Another consideration in the diameter of pin fixation is that pin stiffness is directly proportional to the fourth power of the pin radius (I = πr 4 /4). In other words, as the pin becomes larger, its stiffness increases considerably. Some micromotion is preferred to enhance endochondral bone formation. If the pin is too large, it will be excessively stiff, which may inhibit bone healing. Therefore the surgeon should pick the smallest pin that has stable fixation within the bone. In our experience, most midshaft clavicle fractures in female patients can be stabilized with a 2.5-mm pin, and most male patients receive a 3-mm pin. Seldom do we use a larger pin except in very large patients or in older patients who have age-related increases in their canal diameters. Because the clavicle has very little soft tissue coverage, any type of IM fixation that protrudes from the bone can cause soft tissue problems. It is imperative that the portion of any IM device outside of the bone have the lowest profile possible.


Another point to consider with IM pinning is that these devices frequently cannot be statically locked, thereby providing less rotational and length stability compared with other fixation techniques ( ). However, there are implants now on the market that have an interlocking screw feature. Achieving good IM fit, typically achievable with a 3.0-mm pin, is desirable.


Surgical Technique: Intramedullary Nailing


The advantage of this technique is restoring length, alignment, and rotation with minimal soft tissue stripping, minimal blood loss, and small incisions. The IM device allows compression at the fracture site and load sharing, which are advantageous in the healing of other long-bone fractures. All cases are performed in an outpatient setting under general anesthesia with local anesthesia supplementation.


Patient Positioning


The procedure can be performed in a supine or modified beach-chair position on a radiolucent operating table. We prefer the modified beach-chair position for easier access to the posterior aspect of the shoulder. The torso of the patient is typically at about 45 degrees relative to the floor. A bump is placed under the ipsilateral scapula to help extend the arm and reduce scapula protraction. A large C-arm greatly facilitates pin placement. The C-arm base is brought in from the injured side ( Fig. 14A.1 ). Standard prep and draping is performed, being mindful to include the entire shoulder girdle in the operative field all the way to the sternum. The arm should also be draped free, allowing movement of the arm to facilitate drilling of the lateral fragment and reduction of the fracture.




Fig. 14A.1


A, The patient is placed in the beach-chair position on the operating room table. B, The image intensifier is brought over the top of the patient and draped into the surgical field. The orientation of the image intensifier relative to the torso gives the equivalent of a 45-degree cephalic tilt view of the clavicle.


Intraoperative Imaging


The patient’s torso should be approximately 45 degrees relative to the floor. The gantry of the C-arm should be situated such that the beam of the x-ray is parallel to the floor (see Fig. 14A.1 ). This gives the equivalent of a 45-degree cephalic tilt view of the medial clavicle, which allows the best view of the anterior curve of the clavicle. This orientation also gives a cephalic tilt view of the lateral fragment because placement of a retrograde IM fixation in the lateral fragment is crucial to obtaining anatomic reduction of the fracture. Furthermore, an “anteroposterior (AP) equivalent” view ( Fig. 14A.2, A ) can be obtained by extending the arm, and an “axillary equivalent” view can be obtained by forward flexing the arm ( Fig. 14A.2, B ). It should be noted that plain AP radiographs typically underestimate the length of the fracture because the clavicle is oblique to the x-ray beam.




Fig. 14A.2


A, Extending the arm of the patient gives the equivalent of an anteroposterior view. B, C-arm image. Note the position of the drill bit relative to the equator of the clavicle. C, Forward flexing the arm gives the equivalent of a “near axillary” view. D, C-arm image. Note the exit point of the drill bit halfway between the conoid tubercle and the acromioclavicular joint.


Because of metallic or radiopaque devices on the operative table, the beam of the C-arm may need to be oriented in a posterolateral to anteromedial orientation. In this situation, there may be significant underestimation of the length of the fracture or overlap of the fragments because the clavicle is obliquely oriented relative to the beam of the x-ray. This underestimation will be exaggerated if the C-arm is oriented in an oblique fashion relative to the torso. If necessary, the patient’s shoulder can be brought forward to obtain a better estimation of the true fracture length. It is also important that the entire length of the clavicle can be viewed in one position. After these points are accomplished, the entire case can be completed with the use of a foot pedal to activate the C-arm, thereby negating the need to have a radiology technician. As mentioned, the patient’s arm is draped free to allow movement during the case for better visualization and fracture reduction.


Surgical Method


A 2.5- to 3-cm incision is made in Langer lines over the palpable distal end of the medial fragment. The skin is more easily moved medially than laterally over the clavicle, and most patients have a skin crease in the same area where the incision is made, resulting in a more cosmetically pleasing scar. In fractures with a long oblique pattern, the incision is made slightly more medially and longer to allow elevation of the medial end of the distal fragment. The platysma muscle inserts on the skin near the clavicle, and damage to it may lead to dysfunction of facial expression. Scissors should be used to carefully free the platysma muscle from the overlying skin. Divide platysma muscle fibers longitudinally. Take care to prevent injury to the middle branch of the supraclavicular nerve, which is seen in approximately 50% of patients. It is usually found directly beneath the platysma muscle near the midportion of the clavicle. Injury to this nerve can cause dysesthesia in the anterior shoulder, deltoid, and anterior chest wall in 10% to 29% of cases ( ). The incision should allow access to the less mobile lateral clavicle fragment, which is secured by the coracoclavicular ligaments and the more mobile medial fragment.


With acute fractures, the periosteum over the fracture site is disrupted and usually requires no further division. Any interposed soft tissue or hematoma should be carefully removed from the bone ends. Small butterfly fragments, usually found anteriorly and inferiorly, should be left attached to their soft tissue envelope. These can be cerclaged after primary fixation. The lateral end of the medial fragment is elevated into the incision. The medial medullary canal is identified with a 2-mm drill bit, which can be used to open the initial 1 to 2 cm of the canal. Palpating the medial aspect of the clavicle can help establish this orientation. The canal can be further opened with a 3.5-mm drill bit. Care must be taken to avoid penetration through the anteromedial cortex of the clavicle. Verify drill bit position periodically with fluoroscopy to assure the drill does not pass behind or inferior to the clavicle (see Fig. 14A.2 ) but attempt to keep fluoroscopy times to a minimum. When resistance is met, the drill bit is removed. A 3-mm awl can be used to further open the canal using a short back-and-forth motion but avoid a windshield wiper effect that can result in eccentric reaming. Advance the drill or awl as far past the fracture site as possible without undue force and without penetrating medially. A tap is then used to further open and prepare the canal.


Lateral Fragment Preparation


The lateral canal preparation can be somewhat more difficult, and proper placement is critical to the technique. The ideal exit point in the posterolateral clavicle is halfway between the conoid tubercle and the distal clavicle and at the equator of the clavicle. Although the exit point is at the equator in most patients, some patients may have an exaggerated downward lateral curve to their clavicle. In these cases, the exit point will be more superior; however, it should never be below the equator of the lateral clavicle because this will cause the distal fragment to be flexed upward relative to the medial fragment and may cause excessive rotation of the distal fragment relative to the medial fragment or problems passing the final fixation device past the spine of the scapula. Although it may seem daunting, it is similar to the importance of the piriformis fossa in intramedullary femoral nailing and can easily be achieved with proper drilling and C-arm use.


Locate the lateral fragment of the clavicle bone and maneuver the fragment to enable access to the medullary canal. Although good exposure is preferred, do not violate the coracoclavicular ligaments on the inferior border of the lateral third of the clavicle. If it is too difficult to access the canal because of the patient’s head and neck, externally rotate the involved arm to bring the fragment into more of an AP orientation rather than a medial-lateral orientation. The medial end of the lateral fragment is usually located posterior and inferior to the lateral end of the medial fragment in most cases of lateral impact–mechanism fractures. In “seatbelt fractures,” however, the medial end of the lateral fragment may be located anterior to the medial fragment. After the fragment is identified, it can be grasped with a towel clamp and carefully elevated into the incision. As with the medial fragment, a 2-mm drill is used to establish the orientation of the lateral canal. A 2-mm drill bit is used because the orientation can be changed without compromise of the canal. The orientation of the drill bit should be toward the mid-point of the posterior cortex of the lateral fragment. The surgeon can place the tip of his or her index finger at the “V” formed by the junction of the lateral clavicle and the spine of the scapula with the distal interphalangeal joint of his or her finger at the acromioclavicular (AC) joint and using this as an “aiming device.” This orientation can be checked under fluoroscopy by extending the arm to allow more of an AP view of the distal fragment (see Fig. 14A.2, A ). With this view, the drill bit should be aimed at the “equator” of the clavicle. After this orientation is established, the surgeon can forward-flex the arm to give more of an axillary view of the distal fragment (see Fig. 14A.2, B ). With this view, the trajectory of the drill bit should be aimed toward the posterolateral cortex of the clavicle halfway between the conoid tubercle and the AC joint. The combination of these two aiming points represents the ideal exit point on the lateral fragment. Exiting too high may result in the fragments being flexed superiorly in relation to each other, and exiting too low can result in an apex inferior angulation. Exiting too far medially can cause an apex posterior angulation of the clavicle, and exiting too far laterally can result in an apex anterior angulation. After the orientation is verified, the canal is further opened with a 3.5-mm drill bit, which is passed through the posterolateral cortex. A small incision is then made over the palpable tip of the drill bit. The 3.5-mm drill bit is then removed, and the canal is tapped. Next, the clavicle pin is passed through the lateral fragment from medial to lateral and brought out through the posterior skin incision. The pin should exit just superior to the spine of the scapula.


Fracture Reduction and Final Fixation


After the clavicle pin is driven sufficiently out the posterolateral wound, the pin is unchucked, and the drill is reattached to the opposite (lateral) sharp end of the pin. With downward pressure on the medial fragment and upward force on the elbow to counteract the deformity caused by gravity, the pin can be advanced a short distance into the canal of the medial fragment, which will help temporarily hold the reduction. After reduction is verified under fluoroscopy, the pin is passed into the medial fragment and the reduction again checked with fluoroscopy. The fracture should be anatomically reduced. The final length of the pin can be estimated on fluoroscopy before cutting the pin. It is very important to check the diameters of the fragments after they are reduced. If the diameters are different, this means that there is a rotational deformity, which needs to be corrected. Loss of length caused by fracture comminution can also result in a discrepancy in fragment diameter. When satisfied with reduction, depending on the manufacturer, a locking or bolt mechanism used laterally on the pin can be placed. The pin is then cut flush with the locking mechanism, and any sharp edges are rasped flat. The pin is then advanced the remaining distance into the clavicle until it is seated in the medial-most aspect of the medial fragment with the lateral edge of the pin resting on the posterolateral clavicle cortex. In the case of a long oblique fracture, the fracture can be loosely held reduced with a small bone reduction clamp to prevent shortening of the fracture. In the case of significant comminution, the butterfly fragments can be provisionally fixed by passing #1 or 2 sutures around the clavicle and fragments to cerclage them together. Great care should be taken to keep the needle tip on bone when passing these sutures. If a longitudinal fracture is noted in the medial fragment, a cerclaged suture or wire can be passed around the clavicle to prevent fracture propagation. Fig. 14A.3 shows the preoperative and postoperative radiographs as well as clinical images of a typical case.


Sep 14, 2018 | Posted by in SPORT MEDICINE | Comments Off on Surgical Treatment Options: Mid-Shaft Fracture